Common flue sizing calculator
Preliminary common flue diameter from connected gas input. Velocity check per draft type — final design per BS EN 13384-2.
What this calculator does
Flue sizing helps UK building services engineers with preliminary common flue diameter from connected gas input - velocity check per draft type. The calculation follows BS EN 13384-2 methods used in everyday MEP design — enter your project inputs below for a first-pass result.
Whether you searched for "flue sizing", "flue sizing calculator", or "how to flue size", this page gives you a working tool plus the context to use it on a real job.
When to use it
Use this for early-stage sizing and sanity checks on UK building services work. It is not a substitute for issued calculations — verify against the project specification, drawings, and relevant standard before sign-off.
How to use it
1. Fill in the inputs for your scenario (defaults are starting points only). 2. Click Calculate — results include the method and assumptions where applicable. 3. Verify against the project specification and relevant standard before issuing.
Typical output unit: mm.
Tips
- Defaults are indicative — replace with project-specific values from the architect, structural, or MEP spec.
- For issued calculations, save results in your BuildFlo project and attach to the calculation folder.
- Need the regulation citation? Open BuildFlo chat in the app and ask about flue sizing under UK standards.
---
*Sign up for BuildFlo for the full calculator suite, saved results, and project workspace.*
Frequently asked questions
- How do I size a common flue for multiple boilers?
- Sum connected gas input, apply a preliminary velocity limit by draft type (natural, fan-assisted, condensing), and select a circular flue diameter.
- Is this sufficient for Building Regulations sign-off?
- No. This is a rule-of-thumb screen. Final compliant sizing requires BS EN 13384-2 with manufacturer flue data and the approved chimney system.
- What velocity limits apply to condensing flues?
- Condensing appliances typically allow higher flue gas velocities. Always use the appliance manufacturer's published flue guidance.
Related calculators
- ThermalTemperature designDesign temperatures for UK offices, classrooms, corridors, and plant rooms - winter and summer setpoints from UK design guidance and common practice.
- ThermalU-valueCalculate wall, roof or floor U-values and check against Part L limiting values. Free UK U-value calculator for building services and compliance screening.
- ThermalHeat loadEstimate room or building heat loss and heating plant duty. Free UK heat load calculator for first-pass boiler and emitter sizing.
- ThermalPart O assessmentSimplified Approved Document O check for glazing limits and opening areas in UK dwellings. Free Part O overheating calculator.
- ThermalQuick SAP estimateIndicative SAP/EPC screening before sending to a SAP assessor. Free quick SAP estimate calculator for Part L compliance checks.